Sign inSign up
NVIDIA k8s-cc-manager

dhi.io/k8s-cc-manager

NVIDIA k8s-cc-manager

CIS
linux/amd64
linux/arm64

NVIDIA manager for enabling GPU Confidential Computing and Protected PCIe modes from Kubernetes node labels.

k8s-cc-manager Guides

How to use this image

All examples in this guide use the public image. If you've mirrored the repository for your own use (for example, to your Docker Hub namespace), update your commands to reference the mirrored image instead of the public one.

For example:

  • Public image: dhi.io/k8s-cc-manager:<tag>
  • Mirrored image: <your-namespace>/dhi-k8s-cc-manager:<tag>

For the examples, you must first use docker login dhi.io to authenticate to the registry to pull the images.

What's included in this k8s-cc-manager image

This Docker Hardened k8s-cc-manager image includes:

  • k8s-cc-manager - the Python CC manager application (/app/main.py), which watches the node CC-mode label and drives GPU CC/PPCIe mode changes.
  • gpu-admin-tools - the vendored NVIDIA GPU administration library at /app/gpu-admin-tools, used to query and set CC/PPCIe mode and to reset GPUs over PCI.
  • A Python 3.13 runtime and virtual environment at /app/.venv, with the Kubernetes Python client installed.
  • busybox, which provides /bin/rm for the GPU Operator preStop hook.

The entry point is the virtual-environment Python running the application: /app/.venv/bin/python /app/main.py.

Deploy k8s-cc-manager

k8s-cc-manager is designed to run as a Kubernetes DaemonSet on GPU nodes, normally deployed and managed by the NVIDIA GPU Operator. Replace <version> with the DHI release you want to run and append -dev only when you need the development variant.

Root and privileged requirement

Unlike most Docker Hardened Images, this image runs as root and must run privileged. The manager pokes GPU PCI registers and resets GPUs through gpu-admin-tools, and it reads host confidential-computing state from /sys. A typical pod spec therefore needs:

  • securityContext.privileged: true on the container.
  • Host mounts for /sys and /dev.
  • A ServiceAccount with permission to get, list, watch, and patch nodes (and to list pods in the GPU Operator namespace when component eviction is enabled).

Because the image already runs as root, there is no -compat variant; use the runtime tag directly.

Configuration

The manager is configured through environment variables. Set them in the DaemonSet pod spec:

VariableRequiredDefaultDescription
NODE_NAMEYes-Node name, normally injected via fieldRef: spec.nodeName.
DEFAULT_CC_MODENoonCC mode applied when the nvidia.com/cc.mode label is unset.
EVICT_OPERATOR_COMPONENTSNotrueEvict GPU Operator components before changing CC mode.
OPERATOR_NAMESPACENogpu-operatorNamespace where the GPU Operator is deployed.
CC_READINESS_FILENo/run/nvidia/validations/.cc-manager-ctr-readyReadiness file created once the manager has applied the mode.
KUBECONFIGNo(in-cluster)Path to a kubeconfig for out-of-cluster testing.

These defaults come from the application itself, so the image does not hardcode them; set only what you need to override in the pod spec.

Node labels

Set the CC mode on a node with a label:

# Supported values: on, off, devtools, ppcie
kubectl label node <node-name> nvidia.com/cc.mode=on --overwrite

The manager reports status back on the node:

kubectl get node <node-name> -o jsonpath='{.metadata.labels.nvidia\.com/cc\.mode\.state}'
Inspecting the image

Because this image starts a long-running watch that requires NODE_NAME and real GPU hardware, use --help to inspect the command-line interface:

# Runtime variant (no shell) - print CLI help
docker run --rm dhi.io/k8s-cc-manager:<tag> --help

# Dev variant (includes a shell)
docker run --rm --entrypoint /app/.venv/bin/python dhi.io/k8s-cc-manager:<tag>-dev /app/main.py --help

Common k8s-cc-manager use cases

  • Confidential Computing on GPUs: enable CC mode so GPU workloads run inside a trusted execution environment on supported hosts (Intel TDX or AMD SEV-SNP).
  • Protected PCIe (multi-GPU): enable PPCIe mode across GPUs and NVSwitches in an NVLink fabric.
  • GPU Operator integration: run alongside the NVIDIA GPU Operator, which manages the DaemonSet and coordinates component eviction during mode changes.

For configuration details, refer to the upstream documentation.

Non-hardened images vs. Docker Hardened Images

When migrating from the upstream NVIDIA k8s-cc-manager image:

FeaturePublished upstream NVIDIA imageDocker Hardened k8s-cc-manager
Image referencenvcr.io/nvidia/cloud-native/k8s-cc-manager:v0.4.0dhi.io/k8s-cc-manager:<version>
Userroot (0:0)root (0:0) - required, runs privileged
ShellNoNo (use -dev variant)
Package managerNoNo package manager in runtime variants
Tag formatv0.4.0<version> (no 'v' prefix)
Attack surfaceLarger due to additional utilitiesMinimal, only essential components
DebuggingTraditional shell debuggingUse Docker Debug or the -dev variant

Image variants

Docker Hardened Images come in different variants depending on their intended use. Image variants are identified by their tag.

  • Runtime variants are designed to run your application in production. For this image the runtime variant runs as root and privileged because it manages GPU hardware directly. These images:

    • Do not include a shell or a package manager
    • Contain only the minimal set of libraries needed to run the app
  • Build-time variants include dev in the tag name and are intended for use in the first stage of a multi-stage Dockerfile. These images:

    • Run as the root user
    • Include a shell and package manager
    • Are used to build or extend the application

To view the image variants and get more information about them, select the Tags tab for this repository, and then select a tag.

Troubleshooting

General debugging

The hardened image intended for runtime does not contain a shell nor any tools for debugging. The recommended method for debugging is to use Docker Debug to attach to the container, or to run the -dev variant which includes a shell.

Container exits immediately with a NODE_NAME error

The manager requires NODE_NAME and exits with a non-zero code if it is not set. In a DaemonSet, inject it via a fieldRef:

env:
  - name: NODE_NAME
    valueFrom:
      fieldRef:
        fieldPath: spec.nodeName
GPU access

The manager must be able to reach GPU devices and host CC state. Ensure the container runs privileged and that host /sys and /dev are mounted; otherwise mode queries and resets fail.

Entry point